A Centena Group Company

EcoSEC GPC System with RI and UV Detectors

//EcoSEC GPC System with RI and UV Detectors
  • This Product

    EcoSEC resized.JPG

EcoSEC GPC System with RI and UV Detectors

The EcoSEC GPC System with RI and UV Detectors is an all-in-one GPC system with RI and UV detectors, operating in temperatures ranging from ambient to 60 °C

Category:

Product Description

  • All-in-one GPC system with RI and UV detectors
  • Operates in temperatures ranging from ambient to 60 °C
  • Delivers superior performance and unmatched baseline stability resulting from the unique dual flow RI detector design.
  • The degree of precision in retention time and molar mass determination far exceeds the market standard due to its advanced temperature controlled pumps and the overall thermal stability of the entire system.
  • This high level of engineering results in baselines that stabilize within 90 minutes, exhibit less noise and drift, and deliver exceptional reproducibility day to day, system to system, and site to site.
  • The inherent low dead volume of the EcoSEC GPC System with RI and UV Detectors allows for the use of advanced 15 cm semi-micro columns, which drastically increase throughput and decrease solvent usage, saving you time and money.

Technical Specifications:

Pump
Flow rate 0.010 to 2.000 mL/min in 0.001 mL/min steps
Accuracy ± 2%
Precision ± 0.2%
Max. pressure 25 MPa or 3,500 psi
Safety features Liquid supply stops if pressure rised above the upper limit or drops below the lower limit, Plunger drive count monitoring, Pan for liquid leakage
Stroke volume 7.51 µL

 

Auto-injector
Injection volume 1 to 1,500 µL in 1 µL increments
Number of samples 100, 2 mL injection vials

 

Column Oven
Temperature range Ambient plus 10 °C to 60 °C
Capacity 7.8 mm ID × 30 cm × 8 columns
Accuracy ± 0.5 °C
Precision ± 0.2 ºC

 

RI Detector
Type Bryce (dual flow type),Tungsten light source (1.00 – 1.80 RI range)
Optics Deflection
Cell volume 2.5 µL
Cell pressure limit 0.5 MPa
Noise 2 × 10-9 RIU
Drift 1 × 10-7 RIU/h (THF, 1.0 mL/min)
Dynamic range ±2.5× 10-4 RIU
Temperature control Off, 35°C, 40°C, 45°C
Analog out For connection to third party light scattering and viscometry detectors
Safety features Leak sensor and thermal fuse for circuit block

 

UV Detector
System Dual beam, single flow cel
Light source Deuterium lamp
Wavelength range 195 to 350 nm
Wavelength accuracy ± 2 nm
Bandwidth 8 nm
Range (FS) 0.5, 1, 2, 4 AU/1 V
Response 0.5, 1.0, 3.0 seconds
Drift 3× 10-4 AU/h (254 nm, air in cell, response: 1.0 s)
Noise 2.5× 10-5 AU (254 nm, air in cell, response: 1.0 s)
Flow cell volume 2 µL
Safety mechanism Liquid leakage sensor; lighting time monitoring

 

Instrument
Dimensions 680 (W) × 500 (D) × 550 (H) mm = 2.2′ × 1.6′ × 1.8′
Weight 95 kg = 210 lbs
Dead volume < 20µL

 